Safety Product | Safety Relays | Intrinsic Safety Barriers & Isolated Barriers

TSR := TiGON Safety secureR


Safety Relays

Safety relays are intended to reliably monitor the signals from safety devices at all times and switch off quickly in an emergency. TiGON’s TSR9 safety relays provide optimal safety and a high degree of reliability for plant machinery. The TSR9 enables applications to meet the highest safety ratings in accordance with EN954-1, EN ISO 13849-1 up to PL e, and IEC 62061 up to SILCL 3

General Features

Q&A: Why should I use TiGON TSR9 Series Safety Relays ?

...for safe stops and reliable restarts!!! STAY SAFE FOR LESS!!!

Dual stop signals when the gate is opened...

Timed reset when you cannot see the entire risk area...

Entering or putting a hand or limb into a hazardous area, must cause all machines that can cause a personal injury to stop safely. Many serious accidents occur when machinery is believed to have stopped but is in fact only pausing in its program sequence. The safety relay monitors the gate interlock switch, the cables and gives dual stop signals.

Sometimes a double reset function is necessary to make sure that no one is left behind in the risk area. First, after ensuring no other person is inside the hazardous area, the pre-reset button must be activated, followed by the reset button outside the

risk area within an acceptable time period e.g. 10 seconds. A safety timer and a safety relay can provide this function

 

Supervised reset when there can be a person within the risk area...

Automatic reset for small hatches...

Make Sure that nobody is within the restricted area when activating the reset button. A supervised reset button must be pressed and released before a reset can occur. Many serious accidents have been caused by an unintentional and unsupervised reset.

Where body entry is not possible through a hatch, the safety circuit can be automatically reset. The safety relays are reset immediately when the hatch interlock switch contacts are closed.

   

 

 

Intrinsic Safety Barriers & Isolated Barriers

 

 

 

 

 

 

 

 

Other Product Lines from TiGON

 

 

 

Need more functionalities or features?

 

>> We are fully aware that each case has its unique needs or requirements, please contact us so that we could assist you in finding best solution...

 

 

 

 

 

 

Disclaimer

Safety products sold by TiGON are Safety components only. The purchaser/installer is solely responsible for the application of these components and ensuring all necessary steps have been taken to assure each application and use meets all performance and applicable safety requirements and/or local, national and/or international safety codes as required by the application. TiGON cannot certify that its products, used solely or in conjunction with other vendors’ products, will assure safety for any application. Any person using or applying any products sold by TiGON is responsible for learning the safety requirements for their individual application and applying them, and therefore assumes all risks, and accepts full and complete responsibility, for the selection and suitability of the product for their respective application.

Shanghai TiGON Intelligence Technology Co., Ltd. Copyright @2015-2020
Address: Caohejing Hi-Tech Park, Shanghai 200233, China
Tel/Fax: 86-21-6470-4009 Email:
sales@stitcs.com